T  E  C  H  N  I  C  A  L    D A T  A

Talyrond 30 series

 

TALYROND 30

TALYROND 31

 

 

 

 

 

 

 

 

 

Worktable & Spindle

Worktable diameter

125mm (4.94IN)

125mm (4.94in)

Range of manual centring

±1.25mm (±0.054in)

±1.25mm (±0.054in)

Range of manual leveling

±30 arc minutes

±30 arc minutes

Height of neutral plane

51mm (2in)

51mm (2in)

Speed of rotation

6rpm clockwise nominal

6rpm clockwise nominal

Spindle roundness limit of error (concentric load)*

±0.025mm + 0.00025mm/mm

(±0.975min + 0.0099min/in)

System roundness limit of error (concentric load)*

±0.04mm + 0.00025mm/mm

(±1.57min + 0.0099min/in)

System roundness limit of error (eccentric load)*

±0.04mm + 0.0005mm/mm

(±1.57min + 0.02min/in)

Axial limit of error

0.025mm (0.975min)

0.025mm (0.975min)

Note *: Departure from the least squares circle at 6rpm with 0-50 upr filter (departure may be inward or outward).

Cylindricity

Reference Unit

Straightness/parallelism error (over total column 225mm)**

-3mm(118min)

Parallelism (orthogonal to measuring plane)

30mm over 225mm (0.001in over 9in)

Note *: Straightness/parallelism specification based on calculations from a series of radial traces using an LS circle.

Gauge Range & Resolution

Maximum range

±1mm (±0.039in)

±1mm  (±0.039in)

Resolution at maximum range

0.06mm (2.5min)

0.06mm (2.5min)

Minimum range

±200mm (±0.008in)

±200mm (±0.008in)

Resolution at min range

0.012mm (0.5min)

0.012mm (0.5min)

Measuring Capacity

Max diameter

 

Primary gauge

200mm (8in)

370mm (15in)

Secondary gauge

200mm (8in)

200mm (8in)

Max height

 

Primary gauge

200mm (8in)

225mm (9in)

Secondary gauge (optional)

200mm (8in)

200mm (8in)

Max weight (balanced load)

12kg   (25lb)

12kg   (25lb)

Filter options

Phase corrected 2CR, Gaussian and bandpass filtering available by menu selection.

Filtering is operator selectable from 1-15upr, 1-50upr, 1-500upr, 15-150upr, 15-500upr, and user selected.

Electrical Supply

Alternating supply, single phase with earth (3 wire system)

Voltage

90-260v

90-260v

Frequency

47-63Hz.

47-63Hz.

Consumption (total system)

250VA max, 160w

250VA max, 160w

Environmental Conditions

Temperature:

Operating*** Storage

10-35°C

10-35°C

 

 

-10 to + 50°C

-10 to + 50°C

Temp/time gradient

Less than 2°C/hour

Less than 2°C/hour

Humidity

Operating Storage

30% to 80% relative, non-condensing

 

10% to 90% relative non-condensing

Free air flow rate

1.0m/sec maximum steady

 

*** For optimum accuracy, the instrument should be operated within ±2°C of the temperature at which it was calibrated

Air Source Requirements

Maximum source pressure

8.1bar (120psi)

8.1bar (120psi)

Minimum source pressure

5.4bar (80psi)

5.4bar (80psi)

Air consumption

0.037cu.m/min (1.3scfm)

0.037cu.m/min (1.3scfm)

Operating pressure

4.1bar (60psi)

4.1bar (60psi)

Filtering

5mm (200min)

5mm (200min)

Moisture content – dew point

2°C

2°C

Weights and Dimensions

Main instrument: overall weight

38kg (85lb)

62kg (136lb)

Overall length

330mm (13in)

820mm (32in)

Overall width

280mm (11in)

343mm (13.5in)

PC: overall weight:

30kg (66lb)

Talyrond 30 and 31 conform to the European Electromagnetic Compatibility regulations EN50081-1 and EN50082-1.

 

Note: To allow for supply fluctuations, the preferred air pressure is 80-120lbf/in2(5.4 to 8.1 bar) however where a constant supply pressure can be maintained, a minimum air pressure of 50lbf/in2 (3.4bar) is acceptable. Talyrond 30 Series instruments conform to all applicable requirements of BS EN 50081-1 (1992) and BS EN 50082-1 (1992) and comply with the requirements of the EMC Directive 89/336/EEC.

 

Roundness, concentricity, eccentricity and run out measurements can be made with reference to Least Square Circle, Minimum Zone Circle, Maximum Inscribed Circle or Minimum Circumscribed Circle, flatness and square ness to Least Squares and Minimum Zone.